Protein-pak high res q 5 μm 4.6 × 100 mm
WebbProduct Description. Protein-Pak Hi Res Hydrophobic Interaction Columns (HIC) and HIC Protein Std Mix are ideally suited for use in the characterization of recombinant proteins, … WebbIn addition, quality control testing with defined protein standards helps ensure consistent batch-to-batch performance. Specifications Application Protein Chemistry Anion …
Protein-pak high res q 5 μm 4.6 × 100 mm
Did you know?
WebbProtein-Pak Hi Res Hydrophobic Interaction Columns (HIC) is ideally suited for use in the characterization of recombinant proteins, monoclonal antibodies, and / or ADCs. The use … WebbAs Hep3B cells were treated with relatively higher concentrations (25–100 μg/mL) ... Palo Alto, CA, USA) using a Shim-pack GIS C18 (250 × 4.6 mm, 5 μm). Standard rosmarinic acid and perillaldehyde were ... were then injected into a DB-5MS Ultra column (30 m × 0.25 mm, 0.25 μm). Helium gas was used as the carrier gas at a constant ...
WebbProtein-Pak Hi Res IEX柱包含无孔的、pH耐受的、亲水性颗粒,颗粒表面由多层网络状阴离子交换或阳离子交换官能团组成,粒径分别为5μm (阴离子交换剂)和7μm (阳离子交 … WebbProtein-Pak Hi Res SP, 7 µm, 4.6 mm x100 mm, 1/pk To assist in the characterization of recombinant proteins, monoclonal antibodies, and other biological compounds, Waters …
WebbWaters Corp Protein-Pak Hi Res Q, 5 µm, 4.6 mm x 100 mm, 1/pk, Quantity: Fisher Scientific Fisher Scientific Fisher Healthcare Fisher Science Education Sign Up for Email … WebbProtein-Pak Hi Res Ion-Exchange (IEX) columns were developed to assist in the characterization of recombinant proteins, monoclonal antibodies, and other biological …
WebbIn the above gradient table, the buffer is 20 mM Tris pH 7.4. The initial salt concentration is set to 0 mM to ensure all the analytes are strongly bound onto the column. Then the salt concentration is increased rapidly to 1690 mM and equilibrated for 2 min before the separation gradient starts.
WebbIn addition, quality control testing with defined protein standards helps ensure consistent batch-to-batch performance. Protein-Pak Hi Res Q, 5 µm, 4.6 mm x 100 mm, 1/pk - … caltrain daly cityWebb1 juni 2024 · Injection volume: 0.2–6 μL Column: Waters Protein-Pak Hi Res Q, 4.6 × 100 mm Fluorescence detector: Excitation: 280 nm; Emission: 350 nm Gradient: 70 mM bis-tris propane, pH 9.0, 100–300 mM tetramethylammonium chloride in 20 min at 0.4 mL/min Results and Discussion caltrain 4th and king stationWebb186004931 - Protein-Pak Hi Res Q, 5 µm, 4.6 mm x 100 mm, 1/pk 추가 정보 아데노 관련 바이러스의 빈 및 Empty 및 Full Capsid 함량 측정을 위한 음이온 교환 크로마토그래피 ACQUITY UPLC용 Protein-Pak Hi Res Ion-Exchange (IEX) 컬럼 Protein-Pak Hi Res Ion-Exchange (IEX) Columns and Standards Care & Use Manual ("Protein-Pak Hi Res Ion … coding thingsWebbProtein-Pak Hi Res Q, 5 µm, 4.6 mm x 100 mm, 1/pk. Use the Protein-Pak Hi Res Q Column to characterize recombinant proteins and monoclonal antibodies found in many of the … Waters offers a comprehensive range of analytical system solutions, software, … Expand/collapse global hierarchy Expand/collapse global location How can … May 4, 2024 Spring into Action: Developing Modern LC Methods. Lakeland, FL Type: … View documents related to Waters' business integrity and corporate … First page loaded, no previous page available. Last page loaded, no next page … For the past 60 years, Waters has provided high-value analytical technologies and … Harness the benefits of shopping on Waters.com with 24/7 availability, … The Quality Control Reference Materials portfolio is a unique collection of … caltrain bayshore stationWebb1 jan. 2024 · Perform this experiment in duplicate. In a PCR tube, add 5 μL of thrombin (5 μM) to 40 μL of PBS (pH 7.4). 3.7.3. Add 5 μL of crosslinking TBA (5 μM) for a final volume of 50 μL and final protein and aptamer concentrations of 500 nM. Prepare a separate reaction mixture with 5 μL of unmodified TBA (5 μM) as a control. 3.7.4 cal track lightingWebb2 jan. 2024 · 能否使用 20% 甲醇来储存 Protein-Pak Hi-Res Q 4.6 x 100 mm 色谱柱(部件号 186004931)? - WKB198330 过时的 XBridge BEH C18 保护柱 (186003059) 的当前可用部件是什么? coding test practiceWebb14 apr. 2024 · Briefly, 100 μL of platelet-poor plasma (PPP) and 100 μL of aPTT assay reagent were combined for 1 min at 37 °C, 100 L of CaCl 2 (20 mM) was added, and the clotting times were noted. A total of 200 μL of the PT assay reagent was incubated for 10 min at 37 °C to conduct the PT assays and mixed with 100 μL of PPP for 3 min at 37 °C. caltrain electrification progress video